This line of sensors includes radiometers for special spectral band : UVA, UVB, photosynthetically active radiation, near infrared radiation and illumination according to the CIE Vl CIE curve (human eye). The sensitive element is a photocoltaic cell with interferential filters. All models in this line have normalize output (0-20 mA, 4-20 mA, 0-5 V, 0-300 mV) with Vac or Vdc power supply. All equipments are equipped with electrical discharge safety device
Información en PDF (222 Kb.)

MODELS & CODES

      Descrizione / Description       Codici   
Modelli Fig. Alimentazione:
Uscita:
24Vac
4..20mA
24Vac
0..20mA
12Vdc
0..5V
12Vdc
0..0,3V
C502LUX d1 Luxmeter probe DPA501 DPA502 DPA503 DPA504
C502UVA d1 Radiometer for UVA DPA516 DPA517 DPA518 DPA519
C502UVB d1 Radiometer for UVB. DPA521 DPA522 DPA523 DPA524
C502PAR d1 Radiometer for measuring phytologically active radiation (PAR). DPA506 DPA507 DPA508 DPA509
C502VIR d1 Radiometer for measuring near infrared radiation (VIR). DPA511 DPA512 DPA513 DPA514

TECHNICAL SPECIFICATIONS

   C502LUX C502UVA C502UVB C502PAR C502VIR
Sensitive element Photodiode Photodiode Photodiode Photodiode Photodiode
Spectral range VlCIE 320..400nm 280..320nm 400..700nm 745..815nm
Measurement range 0..100Klux 0..100 Wm-2 0..5Wm-2 0..1500Wm-2 0..200Wm-2
Accuracy 1,5%+10'Wm-2 5%+1 Wm-2 5%+0,1 Wm-2 5%+3 Wm-2 5%+1 Wm-2
Cosine error Fig.d4 Fig.d4 Fig.d4 Fig.d4 Fig.d4
Th.drift (-10+40°) <0,05%/°C <0,05%/°C <0,05%/°C <0,05%/°C <0,05%/°C
Response time 50ms 50ms 50ms 50ms 50ms
Operative temp. -40°+80°C -40°+80°C -40°+80°C -40°+80°C -40°+80°C
Power 0,7W 0,7W 0,7W 0,7W 0,7W
Output cable IP651 connector IP651 connector IP651 connector IP651 connector IP651 connector
Weight (no cable) 1,1Kg 1,1Kg 1,1Kg 1,1Kg 1,1Kg

ACCESSORIES

Code Description
   Electrical connection elements:
MG2251 CIP65 waterproof flying connector for normalized output sensors.
MG1015 3-core cable for connection lines to direct output sensors.
MN1071 7-core shielded cable for connection lines to normalized output sensors.
DWA510 10 m shielded cable with IP65 waterproof connector for normalized output sensors.
DWA525 25 m shielded cable with IP65 waterproof connector for normalized output sensors.
DWA526 50 m shielded cable with IP65 waterproof connector for normalized output sensors.
DWA527 100 m shielded cable with IP65 waterproof connector for normalized output sensors.
   Mechanical connection elements:
DYA051 Collar for attaching sensors or supports to 50 mm Ø meteo mast.
Mounting and Dimension Cosine Response
Spectral response of C502R/LUX and the "CIE" standard observer curve